EPS-95
                

Back


NABL Accredited & TEC Designated EMC Lab

This lab is a part of the Telecom Testing Centre which ITI has built In-house as per the MoU signed with TEC to meet the EMC requirements of the Telecom Equipment launched in the market. This lab can test Industrial, Scientific, Medical and IT equipment for Emission and Immunity requirements of TEC as per International Standards. MIL-STD-461 is followed for Defence and Commercial equipment can be tested as per CISPR 11/22/15/32

SI. No. Test Description
1 Half Day Testing (w/o RS) upto 6 Ghz (4 Hour test time and 1 hour set up time)
2 Full Day testing ( w/o RS) upto 6 Ghz (Total setup and test time 8 hours)
MIL-Standard EMC Testing
1 CE101 (Conducted Emissions, Power Leads, 30 Hz to 10 kHz)
2 CE102 (Conducted Emissions, Power Leads, 10 kHz to 10 MHz)
3 RE101 (Radiated Emissions, Magnetic Field, 30 Hz to 100 kHz)
4 RE102 (Radiated Emissions, Electric Field, 10 kHz to 18 GHz)
5 CS114 (Conducted Susceptibility, Bulk Cable Injection, 10 kHz to 200 MHz)
6 CS115 (Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation)
7 CS116 (Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads, 10 kHz to 100 MHz)
8 RS101 (Radiated Susceptibility, Magnetic Field, 30 Hz to 100 kHz)
9 CS101 (Conducted Susceptibility, Power Leads, 30 Hz to 150 kHz)
10 CS109 (Conducted Susceptibility, Structure Current, 60 Hz to 100 kHz)
COMMERCIAL EMC Testing
1 RE - CISPR 11 ( 30MHz-6 Ghz)
2 RE - CISPR 22 ( 30MHz- 6 Ghz )
3 RE - CISPR 15 (9 KHz to 30 MHz)
4 CE - CISPR 11(150 KHz -30 MHz)
5 CE -CISPR 22 (150 KHz -30 MHz)
6 IEC 61000-4-3 (RF-EMF Immunity Test)
7 IEC 61000-4-2 (Electrostatic Discharge Immunity Test)
8 IEC 61000-4-4 (Electrical Fast Transient / Burst Immunity Test)
9 IEC 61000-4-5 (Surge Immunity Test)
10 IEC 61000-4-6 (Immunity to conducted disturbances)
11 IEC 61000-4-8 (Power Frequency Magnetic Field Immunity Test)
12 IEC 61000-4-11 (Voltage Dips, Short Interruptions and Voltage variations on AC supplies)
13 Compliance Test Report

Certificate of Accreditation


CAB Designation Certificate


Scope of Accreditation


Test Charges


EMC Brochure


image-1

Control Room


image-1

Amplifier Room


image-1

DUT Testing Chamber


Contact Details
Deputy General Manager,
ITI Limited,
Bangalore Plant and R&D,
Dooravaninagar,
Bangalore-560016, Karnataka,India.

Send Mail/Booking Slots

Input Data Form Testing

Phone :+91 97422 89097,
080-26567640
Email:
emiemc_bgp[at]itiltd[dot]co[dot]in, kar_bgp[at]itiltd[dot]co[dot]in,
prateek_bgp[at]itiltd[dot]co[dot]in

Contact